Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Toxicol Pharmacol ; 103: 104282, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37769889

ABSTRACT

The presence of particles fixed in tissue samples due to implant degradation or disintegration plays an important role in post-operative complications. The ability to determine the size, shape, chemical composition and, above all, the number of these particles can be used in many areas of medicine. This study presents a novel, simple metal-based particle detection method using scanning electron microscopy with energy dispersive spectrometer (SEM-EDS). The presence of metal particles in biopsy specimens from long bone nail-fixated implants (10 patients with titanium steel nails and 10 patients with stainless steel nails) was studied. The samples were analysed using automated area analysis based on image binarization and brightness to 255 grayscale. The results were supplemented with histological data and statistically analysed. The method based on the software used was found to be accurate and easy to use and, thus, appears to be very suitable for particle detection in similar samples.

2.
Expert Rev Med Devices ; 19(9): 721-731, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36225151

ABSTRACT

INTRODUCTION: Equinus contracture is a serious disability and attention should be paid to proper and effective treatment. Most attention is given to neurologically impaired patients, but the incidence of equinus contracture is much higher, for example, in post-traumatic patients. In addition to conventional physical therapy, robotic rehabilitation treatment is one of the promising procedures to precede severe contraction cases and the need for surgery. AREAS COVERED: This study aims to cover the description of different types of stationary and wearable ankle rehabilitation devices suitable for the treatment of equinus contracture and point to deficiency in research, clinical trials, and launch of the market. EXPERT OPINION: This review provides insight into ankle rehabilitation devices with a focus on equinus contracture. Due to the fact that robotic devices successfully restore the condition of patients, attention should not be paid only to those with neurological impairments. This paper points that future research should be effectively linked to clinical practice with the aim of covering a wider range of disabilities and make an effort to successfully introduce devices from development into the practice.


Subject(s)
Equinus Deformity , Orthopedic Procedures , Humans , Equinus Deformity/etiology , Equinus Deformity/surgery , Ankle/surgery , Ankle Joint/surgery , Treatment Outcome
3.
Medicina (Kaunas) ; 57(8)2021 Jul 31.
Article in English | MEDLINE | ID: mdl-34440997

ABSTRACT

Background: The standard ATLS protocol calls for chest drain insertion in patients with hemothorax before performing further diagnostic steps. However, if trauma-induced thoracic aortic rupture is the underlying cause, such drainage can lead to massive bleeding and death of the patient. Case report: This report describes a case of a polytrauma patient (car accident), aged 21, with symmetrical chest and decreased breath sounds dorsally on the left. An urgent CT scan revealed subadventitial Grade III thoracic aortic transection with mediastinal hematoma, a massive left-sided hemothorax with mediastinal shift to the right, and other injuries. Stent-graft implantation with subsequent left hemithorax drainage was urgently performed, during which the patient became increasingly unstable from the circulatory point of view. This traumatic hemorrhagic shock was successfully managed at the ICU. Conclusion: Although hemothorax is a serious condition requiring rapid treatment, the knowledge of its origin is of utmost importance; performing chest drainage without bleeding control can lead to circulatory instability and death of the patient. Hence, where aortic injury can be suspected based on the mechanism of the injury, it is beneficial to perform spiral CT angiography for accurate diagnosis first and, in cases of aortic injury, to control the bleeding prior to drainage.


Subject(s)
Aortic Rupture , Hemothorax , Aortic Rupture/complications , Aortic Rupture/diagnostic imaging , Aortic Rupture/surgery , Hemothorax/diagnostic imaging , Hemothorax/etiology , Hemothorax/surgery , Humans , Tomography, X-Ray Computed
4.
J Med Biol Eng ; 37(4): 612-625, 2017.
Article in English | MEDLINE | ID: mdl-28867992

ABSTRACT

Paper focuses on biomechanics, specifically on locking cortical bone screws in angularly stable plates used for the treatment of bone fractures in the medical fields of traumatology and orthopaedics. During extraction of titanium-alloy implants, problems are encountered in an effort to loosen some locking bone screws from the locking holes of an angularly stable plate and the subsequent stripping of the internal hexagon of the screw head. The self-locking of the screw-plate threaded joint was verified by calculation and the effect of the angle of the thread on the head of the locking cortical bone screw on self-locking was evaluated. The magnitude of the torque, causing the stripping of the internal hexagon (the Inbus type head) of a locking cortical bone screw with a shank diameter of 3.5 mm from Ti6Al4 V titanium alloy to ISO 5832-3, was determined experimentally. Also, it was experimentally found that the rotation of the screwdriver end with a hexagonal tip inside the locking cortical bone screw head during stripping of the internal hexagon causes strain of the screw head perimeter and thereby an increase of thread friction. The effect of tightening torque on the possibility of loosening of the locking cortical bone screw from the locking hole of an angularly stable plate was assessed experimentally. From the evaluation of five alternative shapes of locking cortical bone screw heads in terms of the acting stress and generated strains, it follows that the best screw is the screw with the Torx type head, which demonstrates the lowest values of reduced stress and equivalent plastic strain. Based on experiments and simulations the authors recommend that all global producers of locking cortical bone screws for locking holes of angularly stable plates use the Torx type heads, and not heads of the Inbus type or the Square, PH, PZ types.

SELECTION OF CITATIONS
SEARCH DETAIL
...